MatriSpine® Assembled Cervical Spacer
Matrispine®
Bio-implant designed with two cortical endplates supporting a cancellous center for ACDF procedures
*For International Use Only
- Proven Clinical Performance: A prospective study found 100% fusion rates after 12 months in 74 ACDF patients.1
- Osteoconductive: Large cancellous matrix facilitates early bone growth.
- Stability: Textured surface designed to reduce migration.2
- Variety: Multiple footprints in both parallel and lordotic configurations to better match patient anatomy.
- Sterile: Sterilized using proprietary and patented Allowash XG® technology. This technology provides a sterility assurance level of 10-6, without compromising the implant’s inherent osteoconductive properties.3
- Ambient Storage: This implant features Preservon®; a proprietary, glycerol-based preservation technology that allows allograft bio-implants to be stored in a fully-hydrated state at ambient temperature. Preservon eliminates lengthy thawing and rehydrating times, and does not require freezer storage, or compromise biomechanical strength.4
- Uniform dimensions.
Clinical Application
Anterior Cervical Discectomy and Fusion
Freeze-Dried | Description | Sizing |
---|---|---|
ACS5LOR | 3.59mm Posterior Length | 7° Lordosis | 5mm Anterior |
ACS5PAR | 5mm Posterior Length | Parallel | 5mm Anterior |
ACS6LOR | 4.59mm Posterior Length | 7° Lordosis | 6mm Anterior |
ACS6PAR | 6mm Posterior Length | Parallel | 6mm Anterior |
ACS7LOR | 5.59mm Posterior Length | 7° Lordosis | 7mm Anterior |
ACS7PAR | 7mm Posterior Length | Parallel | 7mm Anterior |
ACS8LOR | 6.59mm Posterior Length | 7° Lordosis | 8mm Anterior |
ACS8PAR | 8mm Posterior Length | Parallel | 8mm Anterior |
ACS9LOR | 7.59mm Posterior Length | 7° Lordosis | 9mm Anterior |
ACS9PAR | 9mm Posterior Length | Parallel | 9mm Anterior |
ACS10LOR | 8.59mm Posterior Length | 7° Lordosis | 10mm Anterior |
ACS10PAR | 10mm Posterior Length | Parallel | 10mm Anterior |
ACS11LOR | 9.59mm Posterior Length | 7° Lordosis | 11mm Anterior |
ACS11PAR | 11mm Posterior Length | Parallel | 11mm Anterior |
ACS12LOR | 10.59mm Posterior Length | 7° Lordosis | 12mm Anterior |
ACS12PAR | 12mm Posterior Length | Parallel | 12mm Anterior |